Encoder Switch
Rotate to Increase (+) or Decrease (-) displayed value. Click to select. Press, hold and
rotate for ‘Fast’ data entry. NB: To reset the device to the Factory Default Values,
Power up the ANOVA whilst holding down the encoder switch, it will display ‘DIST
(Distributor), and you select either yes or no to reset the unit.
DMX In/Out
Connect to 3rd party devices or lighting console using standard 5 pin DMX wired
XLR cable. NB – To prevent accidental damage disconnect DMX Consoles or
Controller before selecting ‘DMX Master Mode’ on the ANOVA.
Power Switch
Select DC for an attached DC Input, O, or Battery for the V-Lock Plate (NB : you can
use standard V-Lock Batteries or Anton Bauer Goldmount Batteries with a QR-A200
plate adapter)
Display
This displays the Menu Item or selected value.
Programming Socket
Firmware programming socket. This is not intended for use by users, and is used to
install rmware updates by the manufacturer.
DC Input Socket
Use this 2.1mm DC socket to connect the supplied 15volt 60W AC/DC converter.
You can also run ANOVA from a 14.4volt D-Tap connector via this socket. Only use